MIL312 IP67 Industrial Ethernet Switch

MIL312_R_smMilitary-Rated Gigabit Industrial Connectivity

Red Lion’s Sixnet MIL312 has 12 Gigabit (10/100/1000) Ethernet copper ports. This Layer 3 managed Industrial Ethernet switch features military-style D38999 connectors and link speeds of 10/100/1000 Mbps. With an ultra-rugged case, protected circuitry and advanced software, this switch offers an ideal Commercial Off-The-Shelf (COTS) military solution for battlefield communications, combat vehicles and avionics shipboard. It can also be used with industrial applications that require hardened switches.

Overview

Industrial Switch Product Highlights

  • Layer 3 Ethernet switch increases multi-service network performance
  • IPv4 and IPv6 management
  • IP67/NEMA 6 rated package protects against dust, water, oil, debris and more
  • High-performance switch rated for MIL-STD-810G, MIL-STD-461F and MIL-STD-1275D
  • Military-rated MIL-DTL-38999 Series III connectors protect against vibration, shock, water and more
  • Tough corrosion-proof aluminum case

ApplicationsIndustrial Outdoors

  • Marine and Maritime
  • Transportation
  • Military in-vehicle (per COTS)
  • Aerospace

Ideal for COTS

cots_1

 

 

 

 

Features

Layer 2

  • Spanning Tree Protocol (STP per IEEE 802.1D) plus
    • IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
    • IEEE 802.1s Multiple Spanning Tree Protocol (MSTP)
    • Loopback detection
    • Auto edge port
    • BPDU filter/guard
  • Virtual Local Area Network (VLAN)
    • IP subnet based VLAN
    • Private VLAN isolated
    • Private VLAN
    • GVRP/GARP
    • 802.1v protocol
    • Voice VLAN
    • VLAN translation
    • IPv6 VLANs
    • VLAN trunking
  • Jumbo Frame: 9K
  • IGMP Snooping v1/v2/v3
  • Select Q-in-Q

Layer 3

  • Host table: 8K
  • Route table: 8K
  • Static route table: 512
  • Multicast table: 1K
  • Unicast routing
    • Static unicast routes
    • RIP v1/v2
    • OSPF
    • BGP
  • Multicast routing
    • PIM-DM
    • PIM-SM
    • IGMP v1/v2/v3
    • IGMP v3 proxy
  • IP redundancy
  • Proxy ARP
  • UDP Helper

Switch Properties

  • Ethernet Ports: 12 x 10/100/1000 Mbps (copper)
  • Switching capacity: 128 Gbps/176 Gbps
  • Forwarding Rate: 95.2 Mpps/130.9 Mpps
  • MAC Address Table Size: 16K
  • Packet Buffer Size: 2 MB

Security

  • Port security
  • IP Source Guard
  • Supports IEEE 802.1X port-based and MAC-based access control
  • IP filter configuration for management interface (SNMP, Telnet, Web)
  • RADIUS authentication
  • Access Control List
  • SSH v2
  • HTTPS/SSL
  • MAC filter
  • Dynamic ARP Inspection
  • Link detection package protection

Management

  • Switch Management
    • CLI via console port or Telnet
    • Web management
    • SNMP v1, v2c, v3
    • IGMP snooping (v1/v2)
  • Firmware and Configuration:
    • CLI via console port or Telnet
    • Web management
    • SNMP v1, v2c, v3
    • IGMP snooping (v1/v2)
  • Supports RMON (groups 1, 2, 3 and 9)
  • Supports BOOTP, DHCP for IP address assignment
  • DHCP Snooping
  • DHCP option 66, 67
  • Supports SNTP
  • Supports event/error log, system log
  • Cable diagnostics
  • ATC traffic control
  • Delay reload
  • sFlow
  • CPU Process Utilization
  • Cable Diagnostic
  • IP Clustering
  • Port Mirroring

QoS

  • Priority Queues: 8 hardware queues per port
  • Traffic classification based on IEEE 802.1p CoS, IP Precedence, DSCP, TCP/UDP port number, ACL, and marking
  • DiffServ
  • Supports WRR and strict priority
  • Port rate limiting

IPv6

  • IPv4/IPv6 Dual Protocol Stack
  • IPv6 Address Types: Unicast, Multicast
  • ICMPv6
  • ICMPv6 Redirect
  • IPv6 Path MTU Discovery
  • IPv6 Neighbor Discovery
  • SNMP over IPv6
  • HTTP over IPv6
  • SSH over IPv6
  • Support IPv6 Telnet
  • Support IPv6 DNS Resolver
  • Support IPv6 syslog
  • Support IPv6 SNTP
  • Support IPv6 TFTP
  • Remote IPv6 ping
  • Ping over IPv6
  • Trace route over IPv6
  • IPv6 DHCP relay
  • sFlow over IPv6
  • IPv6 ACL
  • IPv6 DiffServ
  • PIM-DMv6
  • PIM-SMv6
  • MVRv6
Spec

SNMP and Ethernet Standards

  • Ethernet, Fast Ethernet, Gigabit Ethernet
  • Full-duplex flow control
  • IEEE 802.3-2005
  • IEEE 802.3D Spanning Tree Protocol
  • IEEE 802.1w Rapid Spanning Tree Protocol
  • IEEE 802.1s Multiple Spanning Tree Protocol
  • IEEE 802.1Q Virtual LAN
  • IEEE 802.1X IEEE8021-PAE-MIB
  • RFC 1907 SNMPv2-MIB (MIB-II)
  • RFC 2011 IP-MIB (MIB-II)
  • RFC 2012 TCP-MIB (MIB-II)
  • RFC 2013 UDP-MIB (MIB-II)
  • RFC 1493 Bridge MIB
  • RFC 2863 IF-MIB
  • RFC 2819 RMON MIB
  • RFC 2618 RADIUS MIB
  • RFC 2665 Etherlike MIB
  • RFC 2737 Entity MIB
  • RFC 2674 P-bridge, Q-bridge
  • V-Bridge MIB
  • RFC 3036 MAU MIB
  • RFC 1612 DNS Reslover MIB
  • RFC 3411 SNMP Framework
  • RFC 3412 SNMP MPD MIB
  • RFC 3413 SNMP Target MIB, SNMP Notify MIB
  • RFC 3415 SNMP View-Based ACM MIB
  • SNMP Trap Supported:
  • RFC 1215, 1907, 2863, 1493, 1757, 2819
  • Private MIB

Environmental

  • MIL-STD-810G and MIL-STD-108E for environmental performance (see table)
  • Operating temperature: -40 to +75° C (cold startup at -40° C)
  • Storage temperature: -40 to +85° C
  • Humidity: 5 to 95% RH (non-condensing
  • Vent plug for high-altitude operation

EMC

  • MIL-STD-461F for EMI performance. CE101, CE102, RE102 (see table)
  • MIL-STD-461F for EMC performance. CS101, CS114, CS115, CS116, RS101, RS103 (see table)
  • MIL-STD-704 A/E/F and MIL-STD-1275 A/B/D for power protection (POWER INPUT)

Recommended Interface Plugs

  • Ethernet Plug: Aero AE90-365-BN9-9PN
  • Power Plug: D38999/26xA98SA (x = plating option)
  • RS232 Plug: D38999/26xA35PA (x = plating option)
  • Contact distributor for mating connectors

Warranty

  • 5 years on design and manufacturing defects

Power Input

  • Input voltage range: 18-36 VDC (continuous)
  • Input power: 35 W (estimated max. under full load)
  • Reverse polarity protection
  • MIL-STD-1275 for power protection
  • Surge protection: 100 volts for 1 second
  • Transient protection: 15,000 watts peak
  • Spike protection: 5,000 watts (10x for 10 µS) or 250 volts (50x for 100 µS)

Physical

  • Dimensions (L x W x H): 13x6x3.75”
  • Weight (including caps): 8.5 lbs
  • IP67 dust, oil and water-tight package protection
  • LED indicators: port, uplink, system, diagnostic
  • Tough corrosion proof aluminum case
  • Conductive cooling — no moving parts

All specifications are subject to change. Contact Sixnet to learn more.

Connections

Rugged and Compact Military Style Connectors

These switches feature MIL-STD-38999 Series III connectors that are suitable for severe environment, military and industrial networking applications. IP67 Water & Corrosion-proof Connectors

  • Size 23 Contacts – Tested and proven for high speed signals such as 1000 Mbps Ethernet
  • EMI Shielding and ESD Resistance – Solid metal to metal coupling provides superior EMI shielding and ESD protection
  • Contact Protection – Recessed pins in this 100% scoop-proof connector minimize contact damage
  • Moisture Corrosion Resistance – Shells are plated to withstand a 500 hour salt spray exposure
  • Resistance – Improved interfacial seal helps prevent electrolytic erosion of contacts
  • Vibration/Shock – Operates under severe high temperature with vibration, through 200°C
  • Lock-wiring Eliminated – Unique, self-locking, quick coupling connector eliminates lock-wiring
  • Quick Coupling – Completely mates and self-locks in a 360° turn of the coupling nut
  • Compact Size – Ultra compact size to fit into the tightest applications
EMI and EMC
TestStandardSpecification
Conducted EmissionsMIL-ST-461FCD101: Power Leads, 30Hz to 10Hz
Conducted EmissionsMIL-ST-461FCE102: Power Leads, 10 kHz to 10 MHz
Radiated EmissionsMIL-ST-461FRE102: Electric Field, 2 MHz to 18 GHz
Conducted SusceptibilityMIL-ST-461FCS101: Power Leads, 30 Hz to 150 kHz
Conducted SusceptibilityMIL-ST-461FCS114; Bulk Cable Injection, 10 kHz to 200 MHz
Conducted SusceptibilityMIL-ST-461FCS115: Bulk Cable Injection, Impulse Excitation
Conducted SusceptibilityMIL-ST-461FCS116: Damped Sinusoidal Transients, Cables and Power Leads, 10 kHz to 100 MHz
Radiated SusceptibilityMIL-ST-461FRS101: Electric Field, 30 Hz to 100 kHz
Radiated SusceptibilityMIL-ST-461FRS103: Electric Field, 2 MHz to 40 GHz (50V/m)
Ripple TestMIL-STD-1275D 2 V Peak and 7 V Peak Ripple Test
Spike Test (Imported)MIL-STD-1275D+/- 250 Volt Imported Spike Test
Spike Test (Exported)MIL-STD-1275DVoltage Spike Exported from the EUT
Surge TestMIL-STD-1275D40 V and 100 V Surge
Environmental
TestStandardSpecification
Operating TemperatureMIL-STD-810GMethods 501.5: Operating Temperature
Temperature ShockMIL-STD-810GMethod 503.5: Temperature Shock
HumidityMIL-STD-810GMethod 507.5: Humidity
ElevationMIL-STD-810GMethod 500.5: Elevation
Functional ShockMIL-STD-810GMethod 516.6: Functional Shock
General VibrationMIL-STD-810GMethod 514.6, Proc. 1: General Vibration
Steam and Water JetMIL-STD-810GParagraph 4.10 Table II: Steam & Water Jet
Leakage (Immersion)MIL-STD-810GMethod 512.5: Leakage (Immersion)
Salt and FogMIL-STD-810GMethod 509.5
Sand and DustMIL-STD-810GMethod 510.5 Proc. 1
Explosive AtmosphereMIL-STD-810GMethod 511.5
Acceleration TestMIL-STD-810GMethod 513.6 Proc. 1,2,3
Application

With military equipment subject to harsh climates, varying temperatures, shock and vibration, defense requirements are mission critical. Equipment has to be built to withstand extreme stresses without sacrificing performance. Sixnet’s IP67 industrial Ethernet switches are designed to reliably provide high-performance connectivity for the harshest applications. Military rated to support extreme defense conditions, our products link in-vehicle communication systems to support a host of military applications on the land, in the air and on sea. These include land vehicles, ground support facilities, missile delivery systems, bombers, aircraft, UAVs and naval vessels. are designed to reliably provide high-performance connectivity for the harshest defense applications. Military rated to support extreme defense conditions, our products link in-vehicle communication systems to support a host of military applications on the land, in the air and on sea. These include land vehicles, ground support facilities, missile delivery systems, bombers, aircraft, UAVs and naval vessels.

military_312diagram

 

For more information

    Contact Network specialists Ring UK today for professional advice about which system you should go for. We will assess your requirements and research and explain all the options available to you to help you or your client choose a perfect product that meets your needs.

Contact us via our Network Enquiry Form

 [ssba multisite=1]